NFPA 204 Heat and Smoke Vent Inspections

Company News

In a recent Roofing Market Survey conducted by Skyco Skylights, “the vast majority of commercial roofers estimated 40 to 60% of commercial low-slope roofs are due for re-roof or significant maintenance.” Over half of those roofs have outdated skylights and smoke vents in desperate need of replacement.


Fire Marshals and Fire Inspectors are now utilizing the NFPA 204 Standard for Smoke and Heat Venting, which is referenced in the International Building Code (IBC) and International Fire Code (IFC). Smoke vents are a life-safety device for occupants and fire fighters, designed to automatically release the smoke, heat, and hot gases from a burning building in the event of a fire.  


Specifically, the NFPA 204, Chapter 12, Inspection and Maintenance Section is the section that Fire Marshals and Fire Inspectors are now following, which provides mandatory guidelines for annual smoke vent inspections.  

Per NFPA 204 Standard for Smoke and Heat Venting, “Smoke and heat venting systems and mechanical smoke exhaust systems shall be inspected and maintained in accordance with Chapter 12 [Inspection and Maintenance].” Proper inspection and maintenance is paramount for building owners and facility managers, otherwise fines and/or replacement may be costly.


The following is a summary of NFPA 204 scheduling, inspection and maintenance requirements for existing smoke vents:


Requirements: Mechanically opened vents shall be provided with manual release device. Typically, a cord and handle is used to manually activate smoke vent. This will be used to facilitate the inspection and/or for Fire Fighters to ventilate a burning building quick and safe.


Inspection Schedule: Annual inspection schedules for each smoke vent shall be written out detailed with dates and procedures. Any special mechanisms, such as gas shocks, shall be inspected individually each year or as specified by the manufacturer.

 

Details to Note:

• Changes in appearance
• Damage to any components
• Fastening security
• Weather tightness
• Adjacent roofing and flashing condition
• Any deficiencies
• Any other pertinent items


Inspection Actions and Details

• Doors shall be activated by pulling on manual release. Latches should immediately release smoothly and open moving through its designed travel. Doors should open fully without assistance or interruption which would indicate a faulty piston, sticking weather seal, or corroded bearings.

• With doors open, inspect the restraining cable system. Cabling should have ample tension and no frays. Observation shall be made of the whip and travel path of cable, noting any possible obstruction that would delay release of the doors. Any interference shall be corrected by removing obstruction and noted immediately.
 
• All operating levers, latches, hinges and weather-sealed surfaces shall be examined to determine conditions, such as deterioration and accumulation of foreign materials. An operational test shall be performed after removal or correction of any issues.
 
• Inspect the fusible link to determine the date and temperature rating stamped on each fusible link. Fusible links have a life expectancy of 5 years. If during the inspection the fusible link is 5 years or older, it must be replaced with a new fusible link with the identical temperature rating.

• Temperature setting shall be set at a temperature that does not interfere with any sprinkler or first response systems. i.e. Temperature must be set higher than temperature response setting for sprinklers so sprinklers can engage as designed.

 

Reporting: Upon completion of the inspection, an inspection report shall be provided to the Facilities Manager, and maintained on file by the local Fire Inspector. Each vent shall also have an inspection tag attached, indicating date, who inspected and results of inspection.


Maintenance: It is highly advised to consult a skylight and smoke vent professional when it comes to any maintenance on units as in many cases, a new unit is the best and safest option.

 

If you choose to perform maintenance on your units always make sure every item works 100% and do not conflict with other parts. It should be noted that dome only change outs on smoke vents may void the UL Listing and create unintentional liability for the building owner.


Smoke vents are life saving devices. A regular, diligent inspection and upkeep program is needed to ensure the units perform as designed. It is up-to building owners and facilities managers to keep their units in working shape. Inspectors will periodically check in and issue orders to replace or fix.

article Rating

vote data

leave Reply

Repair effected using polymeric membrane system. (photo: Belzona International)
Belzona International  - 04.05.2017, 00:52

The Case for Polymeric Membranes

Belzona International explain why polymeric membranes are increasingly displacing traditional materials used for the repair of flat roofs.

Raising the roof: Poole Hospital’s outpatient department following the refurbishment. (photo: Kemper System)
Kemper System  - 06.03.2017, 23:38

Curing Roof Ailments at Poole Hospital

An odourless, solvent-free waterproofing membrane from manufacturer Kemper System has been used to refurbish the roof of Poole Hospital’s outpatient department in Southern England.

(Photography by Jamie Hooper). (photo: Jamie Hooper)
Dane McGraw  - 10.05.2017, 16:33

Safety in Lead Abatement

Dane McGraw, director of business development at Thomas Industrial Coatings, highlights the key resources that are available in the United States for asset owners and contractors battling lead.

 (photo: Confida FM)
Confida FM  - 02.06.2017, 17:12

New Beginnings for Ayrshire FM Business

The launch of Confida FM promises a bright new future for a wife and husband management team - and the facilities management industry in Scotland...and beyond.

 (photo: WPS Parking Systems BV)
WPS Parking Systems BV  - 15.03.2017, 14:04

Next-generation Parking Technology for Celtic Manor

WPS, one of the UK’s leading parking equipment manufacturers, has won a second contract to provide its ParkAdvance™ technology at the prestigious Celtic Manor Resort in Newport.

 (photo: Infomill Ltd)
Infomill Ltd  - 09.01.2017, 12:22

New Version of PartsArena Pro App

Heating engineers across the UK will enjoy a new, updated version of PartsArena Pro from January 2017 as creator, Infomill rolls out its latest improvements to the leading source of heating parts...

Crocus on site. (photo: Bodet Ltd.)
Bodet Ltd  - 22.09.2016, 20:30

Nursery and Garden Produce Staff Go Biometric

Leading nursery and online garden produce retailer Crocus have just installed the very latest Bodet interactive time and attendance system, to provide accurate and reliable staff attendance data...