Protecting Restoration Projects from Fire

Listen to this article

Cintec North America provides guidance on safeguarding against the risk of fire when buildings are being retrofitted, restored, or modernized following multiple emergencies in the United States and Europe in recent years.

On June 14th, 2017, a fire broke out in the 24 storey Grenfell Tower, widely reported as the worst residential fire to take place in the U.K since the second World War, due to failures by design.

As concerns over fire safety spread through the country, Prime Minister Theresa May ordered a public inquiry. As stated in the final report of the review of building regulations and fire safety, England is by no means alone in needing to improve building safety, as building regulations are a global concern.

Under the terms of EU Regulation (EU) No 305/2011 which repealed Construction Products Directive (Council Directive 89/106/EEC), resistance to fire is one of the essential requirements for which performance tests are required.

Under the terms of EU Regulation (EU) No 305/2011 which repealed Construction Products Directive (Council Directive 89/106/EEC), resistance to fire is one of the essential requirements for which performance tests are required. In Europe, thin-joint mortars have become popular, thus there are a number of situations where fixings are made using organic polymers as either the tie body, or in the form of resin glues. Such ties are not inherently fire resistant and could fail and shorten the life of a cavity wall in a fire, or lead to the collapse of cladding resulting in danger to escaping occupants and fire fighters.

Advertisement

Cintec has always been an advocate for the restoration of safe buildings through fire-resistant anchors, as long ago as 1993 fire tests were carried out by the internationally recognized Building Research Establishment in accordance with BS476(1), ISO(2), and CEN(3). The fire rig was designed for use in the measurement of the performance of Cintec’s™ anchors in a fire situation while subjected to a mechanical load which might be a result of wind suction of fire-induced thermal movement.

Cintec’s remedial anchors survived a two-hour test without failure of any of the samples.

Cintec’s remedial anchors survived a two-hour test without failure of any of the samples. Every sample reached several hundred degrees in the part of the anchor nearest to the fire face. This indicates the anchor system can be recommended for repair work to buildings requiring a fire rating of up to two hours.

Cintec anchors were later, unintentionally, put to the test at the Fullers Brewery in London.

The anchor system had been used extensively to repair and restore the Brewery’s facade. A fierce fire followed, destroying large sections of the building. Despite the brickwork being subjected to extremely high temperatures, tests revealed that the cementitious Cintec anchors did not fail, performing to their original design.

They retained their integrity and could be reused for the repair work. If the anchors were an epoxy or resin type, they would have melted, releasing potentially dangerous fumes in the process and have been easily pulled out, allowing the wall to collapse. One could say that the anchors having survived the fire are in fact fire proof.

In New York City, according to the NYC Buildings Department, adhesive anchors are not permitted to support fire-resistance rated construction unless the use of such anchors meets the conditions set forth in the acceptance criteria. Post-installed anchors in masonry must be designed in accordance with the NYC Construction Codes, describing the masonry substrate type and condition, as well as proof of pull tests.

Howard Zimmerman, the well-known NY Architects, had concerns about the lack of fire ratings for resin-based anchor systems in high rise apartments near Central Park, New York. After reviewing Fire Test Data and performance tests on a severely damaged building after a fire, it was determined that the Cintec System was the best anchor to meet the project engineers’ concerns.

Cintec anchors are the cementitious fire-resistant alternative to resin anchors. Since anchors are made from cementitious grout and stainless steel – which are both reliable construction materials, they easily provided the elusive fire rating typically absent in other systems.

References

1 BS476: Part 20: 1987, Fire tests on building materials & structures. British Standards Institute, London, 1987

2 ISO/DIS 834 – Fire resistance tests – Elements of building construction. Part 1: General requirements for fire resistance testing; Part 2: Fire resistance testing of non-loadbearing elements; Part 3: Fire resistance testing of loadbearing elements

3 CEN prENYYY1, prENYYY2, prENYYY3 (Renumbered equivalents of ISO drafts).

Cintec America Inc

CINTEC North America is a world leader in the field of structural masonry retrofit strengthening. repair and preservation. The principal activity of the company is the design and manufacture of the CINTEC Reinforcing and Anchoring System. a micro cement anchoring and reinforcing technique. Clntec offers complete structural analysis and design services.turnkey solutions. as well as masonry repair and reinforcement anchors used for blast protection,seismic reinforcement, historic preservation and overall building strengthening. CINTEC has worked on projects around the world including the Egyptian Pyramids. Windsor Castle.Buckingham Palace.The Statue of liberty.the Library of Parliament in Canada and the White House complex in Washington DC CINTEC of·HuntValley. MD.and Ottawa Canada and has associated offices in Newport. Wales.UK: Australia; and India.

Author

  • Cintec Worldwide

    CINTEC North America is a world leader in the field of structural masonry retrofit strengthening. repair and preservation. The principal activity of the company is the design and manufacture of the CINTEC Reinforcing and Anchoring System. a micro cement anchoring and reinforcing technique. Clntec offers complete structural analysis and design services.turnkey solutions. as well as masonry repair and reinforcement anchors used for blast protection,seismic reinforcement, historic preservation and overall building strengthening. CINTEC has worked on projects around the world including the Egyptian Pyramids. Windsor Castle.Buckingham Palace.The Statue of liberty.the Library of Parliament in Canada and the White House complex in Washington DC CINTEC of·HuntValley. MD.and Ottawa Canada and has associated offices in Newport. Wales.UK: Australia; and India.

    View all posts

CAMFIL HVAC Filtration Solutions

You may like

We've noticed you are using an ad blocker

Advertising helps bring you fresh independent content. Please disable the adblock plugin or settings in your web browser to access the content you are trying to reach on www.fmindustry.com.