Avoiding HVAC-R Leak Testing Errors

Company News, Heating, Ventilating & Air Conditioning (HVAC), EMEA
Inficon has published a new e-book, "Leak testing of refrigeration, air conditioning and heating systems", which discusses challenges as well as errors commonly encountered when testing equipment.

 

Errors commonly encountered include the following:

 

Wrong method for the test leak rate

A common error in the water bath method is that the tester does not detect bubbles even though there is a leak. Problematic: A basic condition for the suitability of a leak testing or leak detection method is the leak rate limit. Often, however, companies do not pay attention to this in practice. For example, they examine plastic parts using the pressure drop method without considering their deformability and the change in volume caused by the compressed air. The leak rates of the integral leak testing and subsequent leak detection must match.

 

Incorrectly test time settings

At what point in the production process does leak testing make sense? This should be carefully considered. It is usually helpful to check partial components before assembly. If the pre-assembled components fail the series test, the effort is significantly higher - and the time invested in assembly is lost.

 

Contamination of test piece

The following applies to all test methods: Leak testing should always be carried out on completely new test parts. If a component was already in operation in advance and filled with oil or water, for example, small leaks may have clogged up. Before performing leak testing, test pieces must be cleaned and dried.

 

Temperature changes

For integral leak testing according to the pressure decay principle or differential pressure measurement, temperature fluctuations are serious. Minimal temperature fluctuations can alter the measurable leak rate in several orders of magnitude.

 

Test pressure fluctuates

Companies should always fill the test piece with the same constant pressure during the leak testing. Caution is required, however, as the correct filling of some test pieces is only possible after a previous evacuation. With helium testing, for example, tracer gas concentrations are reduced in order to reduce testing costs.

 

Stringer leaks and gross leaks are underestimated

Stringer leaks consist of capillary passages. For successful testing, it must be considered how long it takes for the tracer gas helium to be distributed in such a way that it also escapes from stringer leaks. Therefore, there should be sufficient time between filling and testing to be able to reliably identify stringer leaks.

 

Testers do not know how to perform measurements

For integral leak testing it is recommended to use a reproducible measuring method instead of just relying on the tester's perception. But one should consider how to measure and with which test medium. For example, air leak rates are specified, but helium has a slightly higher dynamic viscosity than air. Therefore, a conversion is required for the exact leak rate.

 

No calibration of the test equipment takes place

Companies should regularly check the operation and accuracy of their testing system with a reference leak (e.g. a calibration leak in a glass capillary), which always causes the same leak rate due to its defined size. If this leak rate is not determined in the testing, the test equipment has a malfunction.

 

Maintenance of the test system is neglected

If companies do not measure leak rates at a test station for days or for weeks that are higher than those at which the test piece still passes the test, this is either a sign of the immense quality of the product - or also an indicator of an insufficiently functioning test system. Therefore, companies should regularly check joints, hoses, test piece holders, etc.

 

“We can do it ourselves”

Think twice before making this decision. It is better to turn to experts and seek comprehensive advice. Selecting the best test method, configuring the test system properly and designing the test process as reliably as possible is a big challenge - therefore professional support is recommended.

 

The top 10 most common errors in leak testing are an excerpt from Inficon's free e-book “Leak testing of refrigeration, air conditioning and heating systems - A guide”, which can be downloaded here https://www.inficon.com/markets/refrigeration/e-book/.

 

 

 

Article rating:

vote data

Leave a reply

 (photo: Rentokil Initial plc)
News Editor  - 01.03.2018, 08:30

Strong Growth from Rentokil Initial

FTSE 100 business services group Rentokil Initial has announced revenue growth of 14.5 per cent and on-going operating profits of 14.8 per cent in preliminary results for the year ended 31 December...

The Pembury Tavern. (photo: )
Delta Security  - 17.10.2018, 09:40

Delta Security Upgrades Security at Hackney Pub

Delta Security s helping to protect patrons, staff and property at Hackney’s Pembury Tavern with the installation of a new security system, including an IP-based CCTV solution, roller shutters and...

 (photo: Sodexo APAC)
Sodexo S.A.  - 09.11.2018, 14:41

Sodexo APAC Embraces Latest Workplace Trends

Sodexo's new APAC House regional headquarters building in Singapore incorporates a suite of digital innovations designed to make work life simpler, more productive and, above all, more enjoyable.

(Photograph courtesy of Tookapic). (photo: )
Marissa Francis  - 05.03.2018, 17:13

The Definition of 'Clever'

Marissa Francis, Heating Ventilation and Air Conditioning (HVAC) Improver with ABM UK, explains why university isn't the only route into facilities management.

New chargepoint installation at Southampton Airport. (photo: Southampton Airport)
AGS Airports  - 26.03.2018, 11:30

Southampton Airport Adds EV Chargepoints

Southampton Airport is helping power the growing number of electric vehicle (EV) drivers on UK roads with the installation of seven new Pod Point 7kW chargepoints in its short stay and priority...

 (photo: )
FM Editor  - 31.05.2019, 02:42

King's College Hospital Contract

Artic Building Services will provide HVAC maintenance services under a new contract with the King's College Hospital NHS Foundation Trust.

Penn State University. (photo: )
FM Editor  - 03.04.2019, 19:36

BACnet Site Manager for Big Building Networks

Vancouver, BC based Optigo Networks will be releasing its Visual BACnet Site Manager aggregation tool for different capture nodes across building and campus networks on 25 April. The tool was...